email info@fireresist.co.uk phone +4407469142764

Certified Fireproof Doors & Windows

We provide fireproof doors and windows engineered to meet UK fire safety standards. Our products are tested and certified to ensure compliance with UK building regulations, offering protection for every type of building.

Fireresist up to 120 minutes
CE & ISO certified
Fireresist fire rated system
Our certifications
EN 14351-1 certificate EI15-EI90 fire rated Aluprof CE certification ISO 9001 ISO 14001 Secured by Design EN 16034:2014 EN 14351-1 certificate EI15-EI90 fire rated Aluprof CE certification ISO 9001 ISO 14001 Secured by Design EN 16034:2014

We work with

fire protection in apartment blocks

Apartment Blocks

We supply fully certified fire‑rated systems and passive fire protection solutions tailored for apartment blocks.

Private Homes

Private Homes

UK‑certified fire‑rated systems and passive fire protection solutions uniquely tailored to private residential properties.

Commercial Buildings

Commercial Buildings

Fire‑rated curtain walls Fireproof doors/windows, smoke vents compliant with British building regulations.

Industrial Buildings

Industrial Buildings

Full range fire‑rated systems and passive fire protection solutions for industrial facilities—including warehouses, factories, etc.

Fire-rated systems

Fire Rated Curtain Walls Arrow

Fire Rated Curtain Walls

Fireproof Doors Arrow

Fireproof Doors

Fireproof Windows Arrow

Fireproof Windows

Smoke Vents Arrow

Smoke Vents

Our products

EI30 MB-86 EI W

MB-86 EI W

Key Advantages The system features a triple-glazed profile with the central section…

Preview
EI120 MB-118EI

MB-118EI

The MB-118EI system is designed for constructing fire rated partitions with a…

Preview
EI30 - EI60 MB-78EI

MB-78EI

The MB-78EI system offers a transparent, fire rated wall solution known as…

Preview
EI30 - EI60 MB-SR50N EI

MB-SR50N EI | MB-SR50N EI EFEKT

The MB-SR50N EI and MB-SR50N EI EFEKT mullion-transom curtain wall systems are…

Preview
Smoke Exhaust Windows

Smoke Exhaust Windows and Roof vents

Smoke exhaust windows and flaps play a critical role in ensuring the…

Preview
EI30-EI90 MB-86 EI D

MB-86 EI D

The MB-86 EI D system offers a versatile solution for thermally insulated,…

Preview
EI15 - EI30 MB-60E EI

MB-60E EI

The MB-60E EI system is designed for creating fire-resistant single and double-leaf…

Preview
EI15 - EI30 MB-78EI DPA

MB-78EI DPA

The MB-78EI DPA system is designed for creating fire-resistant barriers, both internal…

Preview
EI15 - EI90 MB-78EI

MB-78EI

The MB-78EI system is designed for manufacturing fire-resistant internal and external partition…

Preview

Why should you work with us?

We provide fire-rated systems engineered to meet UK fire safety standards. Our products are tested and certified to ensure compliance with UK building regulations, offering protection for every type of building.

Send Quote
UK market Products fit for the UK market
In-house We craft every product in-house
Projects Completed more than 100 projects
Excellence Engineered for Excellence

Our projects

View all projects
Media city, Salford

Media city, Salford

EI60 doors

Project systems MB-86 EI D
Middlewood Locks

Middlewood Locks

EI30, EI60 doors, EI30 windows

Project systems MB-86 EI D MB78 EI

Manufacturing in-house with precision

We are a specialized team that's committed to excellence across manufacturing, service, warranty support, and maintenance of fire-rated doors and windows. All manufactured products are backed by warranty coverage aligned with certification and testing requirements, reinforcing the reliability and durability of our solutions. Our team stays continuously trained on the latest fire-safety regulations, product standards, and technologies, ensuring that every stage of our work reflects sector requirements.

Get in touch

Articles

DIN 4102 B1 Standard – What It Means for Fire Safety Arrow

DIN 4102 B1 Standard – What It Means for Fire Safety

A product data sheet can look reassuring when it lists the DIN 4102 B1 standard, especially if the material is described as flame retardant...

B S2 D0 Fire Rating – How to Get It Right First Time Arrow

B S2 D0 Fire Rating – How to Get It Right First Time

A product can carry a genuine test report and still be wrong for the project. That is the point many specifiers miss when reading a B S2 D0 fire rating...

BS EN 12150 Glass Standard – Are You Compliant? Arrow

BS EN 12150 Glass Standard – Are You Compliant?

Glass can look correct on site and still raise questions later if the wrong standard, thickness, marking or documentation was used...

Fire Front Door Guide – What Most Owners Get Wrong Arrow

Fire Front Door Guide – What Most Owners Get Wrong

A front entrance door is often judged by how solid it looks and how secure it feels. For fire safety, that is not enough...

Fire Doors Flats Guide – Common Mistakes Before Inspection Arrow

Fire Doors Flats Guide – Common Mistakes Before Inspection

Fire doors in flats are easy to misunderstand because many problems are not obvious during a corridor walk...

Fire Door Hinges Guide Before Your Inspection Arrow

Fire Door Hinges Guide Before Your Inspection

A fire door can look good at first glance and still raise concerns during an inspection. One of the most common weak points is the hinges...

As seen on – Daily News, myMOTHERLODE, MINYANVILLE, The Chronicle Journal, openPR, NCN, The Globe and Mail, barchart, BENZINGA

Frequently Asked Questions

What is the difference between fire rated and fire-resistant windows? toggle
Fire rated windows are specifically tested and certified to withstand fire for a designated time (e.g., 30 or 60 minutes), maintaining integrity and sometimes insulation. Fire-resistant windows, while similar, may not meet all testing standards for "fire rated" certification but still offer some level of fire resistance.
Why Can't You Replace Individual Components of a Fire Rated Door System? toggle
Modifying or replacing any single part of a certified fire rated door system can weaken its effectiveness and compromise its fire-resistance capabilities. Fire rated doors are tested and certified as complete units, meaning all elements – including the door leaf, frame, hardware, seals, and other components – are designed and evaluated together to meet specific fire-resistance standards.

Each component within the system is selected and tested for compatibility with the others. When one of these elements is replaced with a part that has not been tested or certified for that specific configuration, the overall fire performance of the door may no longer meet the required standards. Even small changes, such as swapping out hinges, locks, or latches, can significantly alter the door's functionality and fire resistance.

If modifications are necessary, it's essential to consult a third-party certifier who can guide you on the proper steps to maintain compliance. In many cases, they may recommend re-testing the entire door assembly to ensure it still meets the original fire-rating requirements.
Is it possible to install fire rated steel doors in drywall partitions? toggle
Yes, but only if the steel fire rated door system has been specifically tested and certified for use in drywall installations. If a door system has been designed and tested for masonry wall applications, it can only be installed in a drywall system if supported by a technical assessment from the Competent Authority Body (CAB).

This assessment must rely on fire test data and established scientific and engineering principles. Drywall partitions respond differently to fire compared to masonry walls, so a direct substitution without proper evaluation could compromise fire safety.

In cases where sufficient historical test data or published engineering practices are unavailable to support such an assessment, additional indicative testing or type testing may be necessary to verify performance in the new application. Always ensure compliance with technical and safety requirements before installation.
What is the permissible gap between a fire rated door and its frame? toggle
The acceptable gap between a fire rated door and its frame varies based on factors like the door type, frame material, and intended use of the door set. For most fire doors, the gap is generally limited to 2–3 mm around the perimeter, while for steel fire doors, it is typically 3–4 mm.

Always refer to the specific manufacturer's guidelines for the door and frame in question, as the exact allowance will depend on the certified listing and design specifications.
How do I choose the right fire rating for my windows? toggle
The required fire rating depends on the building's design and use,
  • 30 minutes (EW30 or EI30): suitable for low to moderate fire risk areas, such as bedrooms, living rooms, corridors with low fire load.
  • 60 minutes (EW60 or EI60): used for high-risk zones like stairwells, kitchens, lobbies and escape routes.
  • 90+ minutes: used in industrial or hazardous environments requiring extended protection, such as high-rise residential or commercial buildings and hospitals.

Get a Quote!

Tell us about your project and we'll provide a custom quote tailored to your specific needs.

Send Quote
Footer image small Footer image big